1. Help Center
  2. The AxIT System

Calibrating your AxIT System

Calibration procedure:

Each of the AxIT systems devices use sensitive load cell technology to measure forces between them.

It is recommended that you calibrate each AxIT device from time to time to maintain their accuracy.

Simply follow the calibration prompts on the AxIT software before each test with a completely unloaded device to start.

Stomp-IT: Make sure each Stomp-IT device is unloaded on a flat surface during calibration. Calibrate the devices any time you move them to a new location eg: moving from gym tiles to floor boards.

Push-IT: Make sure no pressure is applied to the Push-IT rounded pressure surface during calibration.

Pull-IT: Make sure Pull-IT is sitting flat on its side without any attachments during the calibration process.